摘要:本实验构建了一种基于新型导电聚合物聚3,4-乙撑二氧噻吩(PEDOT)和复合纳米材料PEI-AuNPs-Hemin的仿生传感器。首先在玻碳电极表面先进行了EDOT:PSS通过循环伏安法聚合的PEDOT导电层,再将我们制备的PEI-AuNPs-Hemin复合材料修饰其上制成,最后用来对过氧化氢进行催化研究。 我们的PEI-AuNPs-Hemin复合材料是通过PEI还原氯金酸制备得PEI-AuNPs,再与Hemin结合制备得到。18919
实验过程中我们采用紫外分光广度法与透射电镜的观察确定金纳米粒子的粒径约为20 nm;并利用循环伏安法对过氧化氢在不同扫描速率、不同修饰情况下的催化结果。
关键词:PEI Hemin PEDOT 过氧化氢
毕业设计说明书(毕业论文)外文摘要
Title A catalytic study of hydrogen peroxide-based PEDOT and composite nanomaterials PEI-AuNPs-Hemin biomimetic sensors
Abstract
This experiment constructed a novel biomimetic sensors: the first surface of the glassy carbon electrode was PEDOT prepared by cyclic voltammetry method with EDOT:PSS, then we modified the electrode surface with PEI-AuNPs-Hemin composite material. PEI-AuNPs-Hemin Composites were prepared by reducing Chlorauric acid and then combining with Hemin .
We measured the particle size of PEI-AuNPs-Hemin by methods such as UV absorption and transmission electron microscopy. Then we conducted a study of its catalytic hydrogen peroxide capability to explore the conditions of hydrogen peroxide catalysis and optimize the reaction conditions of the sensor.
Keywords: PEI Hemin PEDOT hydrogen peroxide
目 次
1 绪论 1
1.1 电化学传感器 1
1.2 生物传感器 2
1.3 金纳米粒子 3
1.4聚3,4-乙撑二氧噻吩-聚苯乙烯磺酸(PEDOT-PSS) 4
1.4.1 PEDOT:PSS的概念 4
1.5 聚乙烯亚胺(PEI) 6
1.6 氯化血红素(HEMIN) 7
1.7 过氧化氢 9
2 基于PEDOT和复合纳米材料PEI-AUNPS-HEMIN的仿生传感器对过氧化氢的催化研究 10
2.1 引言 10
2.2 实验部分 10
2.3 实验分析与讨论 12
结 论 17
致 谢 18
参考文献 19
1 绪论
1.1 电化学传感器
1.1.1电化学传感器的原理
电化学传感器由转换系统和识别系统两个部分组成[1]。识别系统的作用:首先识别待测物的某一化学参数(常常是浓度);其次,选择性地与待测物发生作用;最后,将所测得的化学参数转化成传导系统可以产生响应的信号。传导系统接受识别系统的响应信号,并通过电极、光纤或质量敏感元件等将响应信号以电压、电流或光强度等的变化形式,最终使识别系统的响应信号转变为人们所能用作分析的信号传送到电子系统进行放大或进行转换输出信号,检测出样品中待测物的量[2]。
1.1.2电化学传感器的分类
根据修饰物的性质不同,电化学传感器还可分为生物传感器和聚合物传感器。根据输出信号的不同,又可将其分为一下3种[3]。
表1 电化学传感器的分类
类型 特点
电流型传感器 通过保持电极和电解质溶液的界面一恒定的电位,将被测物直接氧化或还原,并输出流过外电路的电流信号,从而实现待测物的检测[4]
电位型传感器 将溶解于电解质溶液中的离子作用于电极而产生的电动势作为传感器的输出,从而实现离子的检测[5] PEDOT和复合纳米材料PEI-AuNPs-Hemin的仿生传感器对过氧化氢的催化研究:http://www.751com.cn/huaxue/lunwen_40232.html