Deteriorationof the interface increases with the increase in the cementdosage. According to test results, although the variation ofcement dosage affects the strength and durability of concreteat ambient temperature, it does not affect the relative residualstrength of concrete exposed to high temperature. The rela-tive residual compressive and flexural strength–temperaturerelationships of concrete were found not to depend on thecement dosages used in this investigation.(2) The compressive and flexural strength–temperature relation-ships can be characterized by two stages:(3) Stage 1: Minor strength loss stage between room temperatureand 200 1C.(4) Stage 2: Major strength loss stage, which begins at a tem-perature of about 400 1C.(5) Comparisons between the experimental residual compressivestrength and the predicted residual compressive strengths asobtained by the BS EN 1992-1-2:2004 and ACI 216-1 weremade. It was found that the relative residual compressivestrength of experimental results agree better with the pre-dicted results in given ACI 216-1 for temperature under400 1C and they agree better with the predicted results ingiven BS EN 1992-1-2:2004 for exceeding 600 1C.(6) Mathematical equations were proposed to predict the resi-dual compressive and flexural strengths of concrete with hightemperatures. These equations can be used to assess the post-fire strength of concrete structures made with concrete mixestypically used in Turkey.(7) The VUT test is found to be an effective tool to assess thedegree of damage in concrete structures exposed to fire.References[1] M.S. Akman, Building Damages and Repair Principles, Turkish Chamber ofCivil Engineers,_ Istanbul, Turkey, 2000 (in Turkish).[2] C.A. Menzel, Tests of the fire resistance and thermal properties of solidconcrete slabs and their significance, Proc. Am. Soc. Test. Mater. 43 (1943)109–1153.[3] C.R Binner, C.B. Wilkie, P. Miller, Heat Testing of High Density Concrete,supplement, Declassified Report HKF-1, U.S. Atomic Energy Commission, June1949.[4] H.L. Malhotra, The effect of temperature on the compressive strength ofconcrete, Mag. Concr. Res. (London) 8 (22) (1956) 85–149.[5] J. Xiao, G. K¨ onig, Study on concrete at high temperature in China—anoverview, Fire Saf. J. 39 (2004) 89–103.[6] ACI 216.1. Standard Method for Determining Fire Resistance of Concrete andMasonry Construction Assemblies (AC- 216.1-07/TMS 0216.1-07), AmericanConcrete Institute, Farmington Hills, MI, 2007.[7] N. Y¨ uzer, F. Ak¨ oz, L. Dokuzer O ¨ zt ¨ urk, Compressive strength–color changerelation in mortars at high temperature, Cem. Concr. Res. 34 (2004)1803–1807.[8] World Trade Center: Building Performance Study: Data Collection, PreliminaryObservations, and Recommendations, FEMA, Report # 403, May 2002.[9] A. Behnood, H. Ziari, Effects of silica fume addition and water to cement ratioon the properties of high-strength concrete after exposure to high tempera-tures, Cem. Concr. Compos. 30 (2008) 106–112.[10] C.S Poon, S. Azhar, M Anson, Y. Wong, Comparison of the strength anddurability performance of normal and high-strength pozzolanic concretes atelevated temperatures, Cem. Concr. Res. 31 (2001) 1291–1300.[11] M.A.H Khandaker, High strength blended cement concrete incorporatingvolcanic ash: performance at high temperatures, Cem. Concr. Compos. 20(2006) 535–545.[12] O ¨ Arı ¨ oz, Effects of elevated temperatures on properties of concrete, Fire Saf. J.42 (2007) 516–522.[13] M.A. Youssef, M. Moftah, General stres–strain relationship for concrete atelevated temperatures, Eng. Struct. 29 (2007) 2618–2634.[14] M. Husem, The effects of high temperature on compressive and flexuralstrengths of ordinary and high-performance concrete, Fire Saf. J. 41 (2006)155–163.[15] I.A. Fletcher, S. Welch, J.L. Torero, R.O. Carvel, A. Usmani, Behaviour ofconcrete structure in fire,
Therm. Sci. 11 (2) (2007) 37–52.[16] L. Biolzi, S. Cattaneo, G. Rosati, Evaluating residual properties of thermallydamaged concrete, Cem. Concr. Compos. 30 (2008) 907–916.[17] M. Li, C.X. Qian, W. Sun, Mechanical properties of high-strength concreteafter fire, Cem. Concr. Res. 34 (2004) 1001–1005.[18] Report No: NISTIR 5934. Fire Performance of High Strength Concrete: AReport of the State-of-the-Art, by L.T. Phan, Building and Fire ResearchLaboratory, NIST Gaithersburg, MD 20899; Dated December 1996.[19] A.M. Neville, Properties of Concrete, Halsted Press, John Wiley & Sons Inc.,New York, 1973.[20] B. Georgali, P.E. Tsakiridis, Microstructure of fire-damaged concrete, A casestudy, Cem. Concr. Compos. 27 (2005) 255–259.[21] BS EN 1992-1-2:2004 Eurocode 2: Design of Concrete Structures. GeneralRules. Structural Fire Design, European Committee for Standardization,Brussels, 2005.[22] EN-197/1. Cement. Composition, Specifications and Conformity Criteria forCommon Cements. British-Adopted European Standard, 2000.[23] TS EN 206-1. Concrete—Part 1: Specification, Performance, Production andConformity. Turkish Standards Institute, Ankara, 2002.[24] E. Tolentino, et al., Effects of high temperature on the residual performance ofportland cement concretes, Mater. Res. 5 (3) (2002) 301–307.[25] ASTM E 119-00A. Standard Test Methods for Fire Tests of Building Construc-tion and Materials, ASTM International, West Conshohocken, PA, 2000.[26] GTG. Mohamedbhai, Effect of exposure time and rates of heating and cooling onresidual strength of heated concrete, Mag. Concr. Res. 38 (136) (1986) 151–158.[27] L.T. Pham, Fire Performance of High Strength Concrete, A Report of the Stateof the Art, Building and Fire Research laboratory, National Institute ofStandards and Technology, MD, 1996.[28] ASTM C597–09. Standard Test Method for Pulse Velocity Through Concrete,ASTM International, West Conshohocken, PA, 2009, doi: 10.1520/C0597-09,www.astm.org .[29] ASTM C78/ C78M - 10 Standard Test Method for Flexural Strength ofConcrete (Using Simple Beam with Third-Point Loading). ASTM International,West Conshohocken, PA, 2009, doi: 10.1520/C0078_C0078M-10, www.astm.org .[30] BS EN 12504-1:2009. Testing Concrete in Structures. Cored Specimens.Taking, Examining and Testing in Compression, European Committee forStandardization, Brussels, 2009.[31] S.Y.N Chan, G.F. Peng, M. Anson, Residual strength and pore structure of high-strength concrete and normal-strength concrete after exposure to hightemperatures, Cem. Concr. Compos. 21 (1999) 23–27.[32] W.M. Lin, T.D. Lin, L.J. Powers-Couche, Microstructure of fire-damagedconcrete, ACI Mater. J. 93 (3) (1996) 199–205.[33] M. Colombo, R. Felicetti, New NDT techniques for the assessment of fire-damaged concrete structures, Fire Saf. J. 42 (2007) 461–472.[34] G. Durmus -, M. Arslan, The effect of high temperature on pore structure ofconcrete, in: 5. International Advanced Technologies Symposium (IATS’09),13–15 May 2009, Karab ¨ uk, Turkey (in Turkish).[35] Y.N. Chan, X. Luo, W. Sun, Compressive strength and pore structure of high-performance concrete after exposure to high temperature up to 800, Cem.Concr. Res. 30 (2000) 247–251.
- 上一篇:耦合侧向扭转频率的不对称三维框架结构英文文献和中文翻译
- 下一篇:在平衡的轴向荷载下K型管节点对应力集中系数英文文献和中文翻译
-
-
-
-
-
-
-
电站锅炉暖风器设计任务书
当代大学生慈善意识研究+文献综述
乳业同业并购式全产业链...
十二层带中心支撑钢结构...
杂拟谷盗体内共生菌沃尔...
java+mysql车辆管理系统的设计+源代码
酸性水汽提装置总汽提塔设计+CAD图纸
河岸冲刷和泥沙淤积的监测国内外研究现状
大众媒体对公共政策制定的影响
中考体育项目与体育教学合理结合的研究