This manual contains instructions that should be observed to ensure your personal safety and to protect the equipment from damage. The instructions are highlighted in the manual by a warning triangle and are marked as follows according to the level of danger: ! Danger indicates an imminently hazardous situation which, if appropriate precautions are not taken, will result in death or serious injury. ! Warning indicates an imminently hazardous situation which, if appropriate precautions are not taken, may result in death or serious injury ! Caution used with a warning triangle indicates an imminently hazardous situation which, if appropriate precautions are not taken, may result in minor injury. Caution used without a warning triangle indicates an imminently hazardous situation which, if appropriate precautions are not taken, may result in property damage. Attention indicates an imminent situation which, if the instructions are not adhered to, may result in an undesirable result or state. Note highlights an important item of information about the product or its use, or indicates a section of the instructions that deserves careful attention as it contains informa-tion that may be beneficial to the user. Trademarks SIMATIC, SIMATIC NET, SINEC and SIMATIC NET Networking for Industry® are registered trademarks of Siemens AG. Other designations in this document may be trademarks whose use by third parties for their own purposes may infringe on the rights of the trademark holder. Safety-related information on the product Before using the product described here, it is imperative that you observe the fol-lowing safety-related information. 49497
Qualified personnel The equipment may be commissioned and operated by qualified personnel only. For the purposes of the safety instructions in this instruction manual, a Qualified Person is one who is authorized to commission, ground and label devices, systems and circuits in accordance with accepted safety standards. Intended use of hardware products Please observe the following information regarding the intended use of hardware products: Caution The device may only be used in applications as provided for in the catalog and in the technical description, and only in connection with non-Siemens products and compo-nents that have either been recommended or approved. Successful and safe operation of this equipment is dependent on proper transport, handling, storage, erection and installation, as well as careful operation and mainte-nance. Before using the supplied sample programs or programs that you created yourself, ensure that running systems cannot endanger persons or damage machines. EG regulation: Commissioning is prohibited until it has been established that the ma-chine into which this component is to be installed is in compliance with the regulations of the 89/392/EWG directive. Preface Purpose of this manual This manual is designed to support you in using the CP 243-1 communications processor. You are provided with information on how to employ this communica-tions processor to communicate via Industrial Ethernet (IE). Prerequisites A prerequisite for understanding how the CP 243-1 works is familiarity with this manual and the "SIMATIC S7-200 Automation System" (MLFB: 6ES7298-8FA21-8AH0) manual. You must also have a basic understanding of the TCP/IP protocol. Target group This manual is directed toward engineers, programmers, commissioning engineers and maintenance technicians with a general knowledge of automation and com-munication systems and human machine interface systems. Sample program This manual contains a sample program that provides you with information and as-sistance in programming the CP 243-1. This sample program was created with STEP 7-Micro/WIN 32 (MLFB: 6ES7 810-2BC02-OYXO) and can be run on an S7-200 CPU, type 224. To run this sample program on another S7-200 CPU, you may have to adjust the configuration of the sample program. Product Information Address label: MAC address The CP 243-1 is delivered with a fixed MAC address. The MAC address is affixed to the underside of the upper door of the device. MLFB number, scope of delivery Product name MLFB Scope of delivery CP 243-1 6GK7 243-1EX00-0XE0 CP, documentation on CD-ROM 1 Introduction Definition and application The CP 243-1 is a communications processor designed for operation in an S7-200 automation system. It is used for connecting an S7-200 system to Industrial Ethernet (IE). The CP 243-1 also facilitates communication via Ethernet for the S7 product family. As a result, S7-200 can be remotely configured, programmed, and diagnosed via Ethernet using STEP 7 Micro/WIN 32. Moreover, an S7-200 can communicate with another S7-200, S7-300, or S7-400 controller via Ethernet. It can also communicate with an OPC server. In the open SIMATIC NET communications system, Industrial Ethernet is the net-work for both the coordination level and the cell level. Technically, the Industrial Ethernet is an electrical network built on the basis of a shielded coaxial cable, twisted pair cabling, or an optical network using a fiber optic cable. Industrial Ethernet is defined by the international standard IEEE 802.3. Continuous communication in the industry sector Industrial Ethernet is an integral part of the SIMATIC NET concept, which together with PROFIBUS and the AS Interface ensures continuous networking of the coor-dination, cell and field levels. Compatibility The CP 243-1 (6GK7 243-1EX00-0XE0) described here can be used for S7 com-munication. The CP 243-1 can be connected to various types of S7-200 CPUs (222, 224, 226 and 226XM): • CPU 222 Rel. 1.10 or higher (Rel. 1.20 or higher is recommended) • CPU 224 Rel. 1.10 or higher (Rel. 1.20 or higher is recommended) • CPU 226 Rel. 1.00 or higher (Rel. 1.20 or higher is recommended) • CPU 226XM Rel. 1.00 or higher (Rel. 1.20 or higher is recommended) A maximum of 2 expansion modules can be mounted on the CPU 222. In contrast, up to 7 expansion modules can be connected to the 224, 226 and 226XM CPUs. A detailed compatibility specification you will find in Appendix D. Attention Only one CP 243-1 should be connected per S7-200 CPU. It cannot be guaranteed that the S7-200 system will operate properly if additional CP 243-1 are connected. The CP 243-1 software is compatible with the following standards: • S7 XPUT/XGET and S7 READ/WRITE • S7-200 I/O bus specifications The position in an S7-200 system in which a CP 243-1 can be operated depends on the firmware version of the S7-200 CPU, see also chapter 3 (Installation) Planning The CP 243-1 is configured using STEP 7 Micro/WIN 32, version 3.2.1. or higher. The CP 243-1 is always delivered with a fixed MAC address. The IP address and the subnet mask either must be configured or they must be retrieved from a BOOTP server via the BOOTP protocol. For the purpose of monitoring connections (Keep Alive), a time can be configured for all TCP transport connections with active and passive partners. A total of 8 connections to other controllers or OPC servers can be maintained at any one time. Programming To program the communication in the user program, use the "Ethernet Wizard" in STEP 7 Micro/WIN 32; see Chapters 4 and 5. Configuration The CP 243-1 firmware is programmed into the Flash memory during production and is permanently stored there. System conditions or dynamic variable contents that are generated during CP 243-1 operation do not survive a loss of power. The CP 243-1 is configured with STEP 7 Micro/WIN 32, version 3.2.1 or higher, and the configuration is stored in the V-Memory of the S7-200 CPU as non-volatile data. Upon booting, the CP 243-1 reads the configuration out of the CPU and ini-tializes itself accordingly. 2 Features and Functions 2.1 Overview The CP 243-1 features the following functions: •
- 上一篇:机床结构动态性能预测英文文献及中文翻译
- 下一篇:单片机介绍英文文献和中文翻译
-
-
-
-
-
-
-
大众媒体对公共政策制定的影响
乳业同业并购式全产业链...
电站锅炉暖风器设计任务书
河岸冲刷和泥沙淤积的监测国内外研究现状
中考体育项目与体育教学合理结合的研究
十二层带中心支撑钢结构...
java+mysql车辆管理系统的设计+源代码
杂拟谷盗体内共生菌沃尔...
酸性水汽提装置总汽提塔设计+CAD图纸
当代大学生慈善意识研究+文献综述