Transducer in the water control system applications Currently, the water level control in a large part of the electrical pumps are not towing gear shift system, no gear shift most of the electrical energy consumed in the water supply to the frequent changes in the pumps stopped. This not only makes the electrical work in inefficient zones, cut short the useful life of electrical and electrical equipment for the frequent failure to stop the high rate, leading to serious waste of water resources, system maintenance, repairs larger workload. 69183
With high living water and industrial water gradually increased, the traditional control methods that are outdated. Originally used for artificial water level control, water level due to the lack of accurate positioning hour monitoring, it is difficult to accurately control the pumps have stopped; Using buoys or mechanical control devices such as water supply situation has made some changes, but because of mechanical failure more devices, poor reliability to maintenance will face great trouble.
Frequency conversion technology, with its superiority in the area of energy efficiency and Hengya pressure control system can be solved by the existence of the above problems. Consider selecting Chanpianji or Plc and transducer combination at the core of the system can achieve a better control results. But in software design, Plc programming of more than Shanpianji concise, and visual; From the hardware interface considerations, Shanpianji circuit slightly complex; From the economic considerations, the Plc processes are mature, cost and small Plc Shanpianji a little, because the system parameters to be adjusted in accordance with the situation on the ground, Plc software, the time parameters adjustments simpler, so more conducive to after-sale personnel. For the above reasons, the selection of the Omron Plc CPM1 series with the transducer as ABB control core, coupled with PSW7 conditioners and WSP300 Biansongqi pressure, the effect was very good control, software design simple hardware interface simple and feasible, reliable, the entire system Xingjiebi very high.
Transducer in the water system in conjunction with the introduction of small Plc technology not only change the traditional use of water control valves, and in energy conservation, Hengya control, are very good results, the paper introduced a transducer --PLC control technology in the pump control applications.论文网
Control system using one Taiwan transducer can bring three pumps, pumps can work at the frequency pump in the conventional model can work in the frequency conversion pump model. At the pump only in frequency conversion or one of the working frequency mode through two relays efficient ensure its security and reliability. System structure as figure 1 shows, the use of placement in the life of water pressure Biansongqi water pressure signal transmission to the regulator, in accordance with the regulator to set the value and warning of lower compared to send signals to the Plc and the transducer, the system has stopped pumping from regulator pressure level signals and transducer frequency range signal, if the low pressure, regulator to the Plc a pressure lower signal Plc activation transducer, and a frequency conversion 1st pumps work state, and the output frequency gradually increasing, after a period of adjustment, such as pressure is low, then, Plc for 1st pumps in the frequency of work, 2nd pump frequency conversion work at the state pumps, such as pressure is low, 2 pumps at the frequency for the state and make the state 3rd pumps in frequency conversion work, and so on. When the pressure regulator to limit the police on duty, regulator output reduction, transducer frequency reduced to the low frequency range set value at a given frequency transducer signals to the lower PLC,PLC According to Kai principle pause control pump operation sequence, for example, Plc received lower frequency signals, the system pumps state is the frequency 1st, 2nd-frequency, 3rd frequency conversion, the first time 1st pumps activated, the first stop, then as the pressure was high, then stopped on the 2nd pumps. Each system is used for slow start, high-speed operation in order to enhance operational efficiency.