    A free connection can only be used if your S7-300 or S7-400 system is to be operated

    as a server. Free connections do not have to configured in STEP 7. Standard

    S7-300 and S7-400 systems are set up to communicate via free connections.

    If you would like to make use of the mechanism for free connections in your S7-300

    or S7-400 system, the client side for each of these connections must still be configured.

    In STEP 7 Micro/WIN 32, there is not difference between use of these

    connections and communicating via connections that were configured in the S7-

    300 or S7-400 system. For free connections, you must merely ensure that the first

    byte of the TSAP over which these connections pass to the S7-300 and S7-400

    systems is always assigned a value of 0x03. The second byte of the TSAP is derived,

    as described above, from the rack and position number of the CPU used in

    your S7-300 or S7-400 system.

    Note

    S7-200 systems do not support free connections. This means that you must configure

    each connection in an S7-200 system, regardless of whether your system is

    to be operated as a client or server.

    4.6 Behavior of CP 243-1 in the event of configuration errors

    If the CP 243-1 recognizes an invalid configuration, it attempts to retrieve its

    TCP/IP address parameters (IP address, subnet mask, IP address of Gateway) via

    a BOOTP service. The CP 243-1 continues the attempt for approx. 1 minute. If it

    does not receive a response from a BOOTP service within this time or if the response

    is invalid or faulty, the red LED (“SF“) flashes for approx. 30 seconds. This

    procedure is cycled through until the CP 243-1 either finds a valid configuration in

    the S7-200 CPU memory or receives a valid response from a BOOTP server.

    If the CP 243-1 receives a valid BOOTP response, it configures itself as follows:

    • IP address, subnet mask and IP address of the Gateway are taken over from

    the BOOTP response

    • The transmission type is set to “Auto Negotiation” (Auto Detect Communications).

    • The Keep Alive time for connections is set to 30 seconds.

    When configured in this way, the CP 243-1 is able to access the S7-200 CPU from

    STEP 7 Micro/WIN 32 through Ethernet. A new valid configuration can now be

    loaded in this way. Communication with other controllers is not possible under

    these conditions. After a reset, the CP 243-1 configures itself in accordance with

    the new configuration.

    Note

    The Auto Negotiation mode (Auto Detect Communications) only operates if all connected

    network components support this mode.

    4 组态

     4.1组态选项

    一个S7-200系统可以通过CP 243-1A和另论文网一个S7-200系统进行通信,也可以和一个S7-300系统,S7-400系统或者基于OPC的系统进行通信。

    在一个S7-200系统中有两种方法组态这种通信方式:

    使用STEP 7 Micro/WIN 32 v3.2.1或者更高的版本的组态方式

    使用S7-200用户程序的组态方式

    注意

    如果CRC进程被关掉,那系统只能通过S7-200用户程序进行组态。

    在CP 243-1的CRC检查被关掉后,组态数据就不再能以关于预期和意想不到的变化的一致性进行检查,在CP 或者说是组件与网络连接的情况下,无法保证它将正确运行。

    在这两种情况下,组态数据都存储在S7-200的CPU 的数据块中。

    每当CP243-1重启一次是,数据就从那个地方读取一次。

    注意

    为了保护CP243-1中的组态数据,如果系统进入中频状态,那么这些数据将被存储在S7-200的非易丢失的数据存储区域中。

  1. 上一篇:振动台实验和动态响应地震后的钢筋混凝土建筑英文文献和中文翻译
  2. 下一篇:机床结构动态性能预测英文文献及中文翻译
  1. 汽车乘员舱的声振耦合英文文献和中文翻译

  2. 立体光照成型的注塑模具...

  3. 数控机床英文文献和中文翻译

  4. 工业机械手英文文献和中文翻译

  5. 低频振动的铁路车轴的状...

  6. 接头的形状对沥青塞接头...

  7. 数控加工技术英文文献和中文翻译

  8. 当代大学生慈善意识研究+文献综述

  9. 大众媒体对公共政策制定的影响

  10. 乳业同业并购式全产业链...

  11. 十二层带中心支撑钢结构...

  12. 杂拟谷盗体内共生菌沃尔...

  13. 中考体育项目与体育教学合理结合的研究

  14. 酸性水汽提装置总汽提塔设计+CAD图纸

  15. 电站锅炉暖风器设计任务书

  16. 河岸冲刷和泥沙淤积的监测国内外研究现状

  17. java+mysql车辆管理系统的设计+源代码

  

About

751论文网手机版...

主页:http://www.751com.cn

关闭返回