菜单
  

    when  the  droplet  sizes,  calculated  from  the  phase
    difference detected  in different positions, were  the
    same  or  their  differences  were  within  10%,  we
    regarded  them  as  the  spherical  droplets.  There-
    fore,  it  is  found  that  there  are  ligaments,  non-
    spherical  droplets  or  large-sized  droplets  that
    exceed  the  measurement  range  of  the  PDPA  sys-
    tem  used near  the central part  of the  spray. Mean-
    while,  after  the  central  part  of  the  spray  passes
    through  the measurement point,  the  detecting  fre-
    quency  of  the  droplets  increases  prominently.
    From  these  time-resolved  evolutions of  the  dro-
    plet  size,  the  structure  of  the  diesel  spray  can  be
    divided  into  the  three  main  parts,  as  depicted  in
    Fig.  3 :  (a)  the  leading edge  affected  by  the  surro-
    unding air  and  composed  of small  droplets;  (b)
    the  central  part  surrounded  by  the  leading  edge
    and  mixing  flow  region,  and  scarcely  affected  by
    the  surrounding air  ;  (c)  the  trailing edge  formed
    after  the  central  part  passed.
    Figure  4(a)  shows  the  results  for  the  5-hole
    nozzle.  Slightly  large-sized  droplets  are  detected
    at  the  leading edge  and  central  part  of  the  spray,
    and  the detecting frequency of the droplets  is  low.
    Numerous  droplets  over D >40  ,am  are  measured
    in  the  beginning region of the  trailing edge  of the
    spray.  After  1.51 ms  from  SOl,  the  size  of  most
    droplets  shows  below  25  ,am,  but  large-sized
    droplets  are  detected  irregularly.  The  AMD  is
    approximately 25  ,am during  the  injection period,
    but  it  maintains  the  value  of  about  10,am  after
    1.5 ms  from  SOl. The  trend  of the  SMD  variation
    is  quietly  similar  to  that  of  the  AMD,  and  the
    difference between  the AMD  and  the  SMD  is  not
    so  large.  It means  that  the  droplet  distribution  is
    quietly  uniform  because  the  SMD,  which  is
    defined as  the  ratio of volume  (d  a)  to  surface area
    (d2),  has  the  weighting  factor  to  the  large-sized
    droplets,  so  that  the  difference between  the  AMD
    and  the  SMD  decreases  when  the  droplet  size
    shows  the  quietly  uniform  distribution.
    Figure  4(b)  shows  the  results  for  the  single-
    hole  nozzle.  The  trend  of  the  droplet  diameter
    distribution with  time  from  SOl  is  similar to  that
    for  the  5-hole  nozzle, but  large-sized droplets  are
  1. 上一篇:高层建筑钢筋混凝土承台设计英文文献和翻译
  2. 下一篇:模糊PID控制器英文文献和翻译
  1. 柴油机连杆英文文献和中文翻译

  2. 低燃油中的硫的氧化模型...

  3. 船用柴油发动机的活塞组件英文文献和翻译

  4. 电站锅炉暖风器设计任务书

  5. 当代大学生慈善意识研究+文献综述

  6. java+mysql车辆管理系统的设计+源代码

  7. 杂拟谷盗体内共生菌沃尔...

  8. 十二层带中心支撑钢结构...

  9. 河岸冲刷和泥沙淤积的监测国内外研究现状

  10. 乳业同业并购式全产业链...

  11. 酸性水汽提装置总汽提塔设计+CAD图纸

  12. 中考体育项目与体育教学合理结合的研究

  13. 大众媒体对公共政策制定的影响

  

About

751论文网手机版...

主页:http://www.751com.cn

关闭返回