摘要目前,在空调冷冻设备行业内用满液式蒸发器替代干式蒸发器正成为一种趋势。满液式蒸发器能让离心机或螺杆机能效最大化,其管外为制冷剂,管内通水,制冷剂在管外蒸发,液态制冷剂与载冷剂通过管壁的换热效率比干式蒸发器高得多。满液式蒸发器能够显著提高换热系数,但其设计制造上存在许多难点和运行上的安全问题。。本文归纳了满液式蒸发器的一般设计要点,设计了一套制冷量1000kw的满液机组,完成了满液式蒸发器的系统设计和结构设计。33151
关键词 满液式蒸发器 满液机组 螺杆空压机
毕业论文设计说明书中文摘要
毕业设计说明书外文摘要
Title Design of a flooded evaporatot and Match of refrigeration unit
Abstract
At present,it is becoming a trend in the Air-condition chiller manufacturing industry that the flooded evaporator takes place of the dry-type evaporator.The flooded evaporator usually match with centrifuge or screw compressor,refrigerant evaporates outside the tube while water flows inside the tube.Its heat transfer efficiency between liquids is much higher than the dry-type evaporator,but there are many difficulties in manufacturing and operating safely.This paper summarizes key points in designing the flooded evaporator, also designs a system of 1000kw and completes the strcture design.
Keywords flooded evaporator flooded chiller screw compressor
目次
1 引言 7
1.1 满液式蒸发器的应用背景 7
1.2 满液式蒸发器与干式蒸发器的区别 7
1.3 满液式冷水机组运行过程中需要注意的地方 11
1.3.1 冷冻水防冻结冰保护 11
1.3.2 油平衡问题 11
1.3.3 液位高度控制 11
2 满液式冷水机组的设计要点 12
2.1 满液式蒸发器的一般设计要点 12
2.1.1 half bundle满液式蒸发器结构图2.1 12
2.1.3 full bundle满液式蒸发器 13
2.2 满液式冷水机组制造及监督检验重点 14
2.2.1 焊接 15
2.2.2 耐压试验 15
2.2.3 容器外观见证 15
2.3 满液式蒸发器换热管的优化 15
2.3.1 高效换热管 16
2.3.2 排管的优化设计 16
3 设计计算书 19
3.1 热力计算 19
3.1.1 制冷剂流量的确定 19
3.1.2 冷冻水流量的确定 19
3.2 传热管的设计 21
3.3 传热系数的确定 21
3.3.2 平均对数温差 21
3.3.3 管内换热系数 22
3.4 结构设计计算 25
3.4.1 筒体 25
3.4.2 容器其他部件 25
3.4.3 连接管的确定 26
4 强度计算 28
4.1 前端管箱筒体计算 29
4.2 前端管箱封头计算 30
4.3 延长部分兼作法兰固定式管板 30
4.4 换热管 31
5 冷水机组的匹配 32
5.1 压缩机组 32
5.2 冷凝器 34
5.3 回油器 36
5.4 气液分离器 38