摘要:利用AT89S51单片机、ADC0809 A/D转换器、DS18B20温度传感器和MQ-2气体传感器设计了火灾报警装置。本装置通过温度和气体传感器采集数据,经A/D转换器转换为数字信号后送入单片机,判断其所采集的气体和温度数据是否达到设定的警戒值,从而实现火灾报警功能。本系统具有结构简单、使用灵活、价格低廉、性能可靠、实用性强,且成本低等优点,市场应用前景广阔。53744
毕业论文关键词: AT89S51,ADC0809,DS18B20,火灾报警
Abstract: This paper, by using single chip microcomputer AT89S51, DS18B20 temperature sensor, ADC0809 conversion circuit and MQ - 2 gas sensor a fire alarm device is designed. By temperature and gas sensor to collect data, converted to A digital signal by A/D converter into MCU, after the last judgment whether gas and temperature of the collected signal to set the alert value, to achieve the purpose of the fire alarm. This system has simple structure, convenient use, low cost, reliable performance, strong practicability, and low cost advantages, broad application prospect in the market.
Key words:AT89S51,ADC0809,DS18B20,the fire alarm
目录
1 绪论 4
1.1 火灾报警装置的意义 4
1.2 火灾报警装置的发展趋势 4
2 系统总体方案设计 5
2.1 火灾产生原因 5
2.2系统预期目标 7
2.3 系统设计方案 7
3 系统主要器件选择 8
3.1 MQ-2烟雾选择 8
3.2 AT89S51主控器 11
3.3 ADC0809转换电路 14
4 系统硬件电路 15
4.1 单片机外围接口电路 15
4.1.1 复位电路 15
4.2.2 晶振电路 15
4.2 信号处理电路 16
4.4 报警电路 16
5 系统软件设计 18
5.1 软件开发环境 18
5.2 系统程序设计 18
5.2.1 主程序流程图 18
5.2.2主程序初始化流程图 19
5.3 数据采集子程序 20
5.4 火灾判断与报警 22
结 论 24
参考文献 25
致 谢 26
1 绪论
1.1 火灾报警装置的意义
伴随着时代的不断发展,居民用火和用电量越来越多,因为引发的火灾发生的事件也有增无减。一旦引发失火,火势蔓延,消防人员无法及时赶到,现在人员缺乏安全尝试,灭火器材不能大面积扑灭火势,逃生通道拥挤等情况不仅会损失大量财产,也严重威胁人们的生命安全。
有报道称,英国每一年发生50000多起以上的严重火灾,火灾不仅能够造成大量的家庭财产损失同时也会造成重大的人员伤亡人员,更严重的还会殃及鱼池,连左邻右舍,甚是整栋楼都产生不可预估的财产损失,加上现在人口密集度巨大,而中国当代房屋的寿命仅仅只有30余年,更让一场火灾变得如同魔鬼变般摧毁着人们身心财产。而绝大多数火灾的起因,都是由于当事人疏于预防,对火灾的发生感觉很遥远,与自己关系不大。