摘要:随着社会经济的发展,人们对居所的要求越来越高,尤其对于新的居住场所由于装修所带来的气体污染问题越来越严重。因而室内有害气体检测与报警系统的设计就显得格外重要。本设计可以避免气体中毒事故的发生,对保障居民人身健康具有重要意义。60766
本系统采用MQ-138传感器、单片机AT89C51、模数转换芯片ADC0832、LCD1602液晶显示器组成。系统中的信号采集电路用于对气体浓度进行检测,并且通过AD转换器将模拟信号转换为数字信号送入单片机,然后运用LCD显示器显示出当前有害气体浓度。如果有害气体的浓度达到报警值时将会触发声光报警,进而提示人们远离该场所。本设计通过Keil软件进行编程,运用Proteus软件进行系统仿真,最终实现了室内有害气体的检测与报警系统的设计。
毕业论文关键词 :室内环境检测,报警,单片机,传感器
Abstract:With the development of social economy, people more and more high to the requirement of residence, especially for a new place to live because decorate the gas pollution problem more and more serious. And indoor harmful gas detection and alarm system design is especially important. This design can prevent gas poisoning accidents, is of great significance for ensuring residents health.
This system adopts MQ-138 sensor, single chip microcomputer AT89C51, modulus conversion chip ADC0832, LCD1602 LCD. System of signal acquisition circuit is used for to test the gas concentration, and through the AD converter converts analog signals to digital signals into a single chip microcomputer, and then use the LCD display shows the current concentration of harmful gases. If the concentration of harmful gas reaches the alarm value will trigger the sound and light alarm, and prompt people to stay away from this place. This design through the Keil software programming, the use of Proteus simulation software, finally achieved the indoor harmful gas detection and alarm system design.
keyword: indoor environment detection, alarm, MCU, sensor
目录
1. 绪论 4
1.1 本课题的研究背景与意义 4
1.2 室内环境检测系统的发展情况 4
1.3 设计目的及内容 5
2. 系统的总体框架设计 6
2.1 单片机的选择 6
2.2 气体传感器的选择 6
2.3 系统电路框架设计 6
3. 主要元器件介绍 8
3.1 气体传感器的简介 8
3.2 A/D转换器的简介 9
3.2.1 A/D转换器性能参数 9
3.2.2 引脚介绍 9
3.3 单片机简介 10
3.3.1 单片机的功能特性 10
3.3.2 单片机最小系统 10
3.3.3 单片机时钟电路 10
3.3.4 单片机复位电路 11
3.4 LCD液晶显示屏 12
4. 模块电路设计 14
4.1 单片机最小系统电路 14
4.2 信号采集和A/D转换部分电路 14
4.3 显示部分电路